Leading Waste Incinerator

Basic Info.

Model NO.:construction of fire brick incinerator
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste may utilize in this gear?  A: This gear to medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation material, liquid waste and gas waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity  A: Average Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour), not indicate any waste material.

Clover incinerator utilize time daily to 24 hours. Between every feed/combustion time, you will find approximately 0.5-1 hours cooling time plus time to get feeding waste. Actual combustion time daily is about 16 hours. The life span of incinerator between 5-10 year according to use. 

Ordinarily, we proposal little lab, little clinic use capability under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output around 2kgs per people per day. If there are 200 sickbed at the clinic, that’s mean you need one incinerator capability around 400kgs daily, change to power per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you may use capacity from 30-50 kgs each hour incinerator.  *The best way to compute Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Meeting and Testing  A: We supply all documents and incinerators easy to installation and operation. Customer can send people visit our factory to learn installation and operation. Generally, we don’t send engineer to local website if not ask. The dispatch cost is additional according to order. 

Q: Combustion Temperature  A: The first combustion chamber: 800-1000 centi degree.  The next combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode  A: Default Control manner is common control case. PLC mode according to model and order. 

Q: Operation and maintenance costs  A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according model, utilize situation. 

One individual can service 02 unit incinerators. The staff should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to safeguard worker self with essential protection element. 

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm
Arabic Arabic English English French French German German Italian Italian Portuguese Portuguese Russian Russian Spanish Spanish